ROBUS PIR Motion Sensor Repair & Failure Analysis
WizardTim
Troubleshooting and repairing a broken PIR (Passive Infra-Red) motion sensor sold under the ROBUS brand (RU360-01) and then taking a closer look at the failure mode and discussing the robustness of X class safety capacitors and a teardown of the failed capacitor and speculation about the root cause of the failure.
@EEVblog2 video discussing film capacitor failure modes with Ron Demcko (KYOCERA AVX) https://www.youtube.com/watch?v=9V99J22aiLE
00:00 - Looking at the failed PIR sensor 03:15 - Verifying fault condition 04:52 - Testing capacitors 07:19 - Replacing capacitors 09:22 - Verifying repair 10:08 - Capacitor Impulse withstanding tests 13:34 - Failed capacitor teardown 16:14 - Outro
REF: WT-YT-V-21 ... https://www.youtube.com/watch?v=W4ifnLcAIDM